铁路数字信号电缆成缆绞合工艺的参数化建模与优化研究

    Parameterized Modeling and Optimization of Cabling Stranding Process for Railway Digital Signal Cables

    • 摘要: 成缆绞合是决定铁路数字信号电缆所用缆芯结构稳定程度及信号质量的关键工序。就 TB/T 3100.1—2017《铁路数字信号电缆 第1部分:一般规定》中的“皮-泡-皮”三层共挤绝缘方式的成缆绞合工艺而言,文中整合绞合节距、节径比、绞入系数及绞合角,构建联动参数化运动学模型,并借助仿真软件对四线组进行电磁仿真(节径比为15~25),同时分析退扭传动比对屏蔽层褶皱的影响。仿真表明:节径比由22降至18时,非屏蔽星形四线组电容耦合系数从93 pF·km−1降至78 pF·km−1;退扭传动比控制在0.95~1.05后,1000 kHz近端串音衰减由52 dB提升至56 dB以上。据此判断,基于参数化联动模型的仿真驱动工艺优化是缩短调试时间、提高成品率的可行办法,亦能为高速铁路数字信号电缆工艺带来可量化理论支持。

       

      Abstract: Cabling and stranding is the key process that determines the structural stability of the cable core and the signal quality of railway digital signal cables. For the cabling process of such cables employing the “skin–foam–skin” triple-layer co-extruded insulation specified in TB/T 3100.1—2017 Railway digital signaling cable–Part 1: General specificationgs, the stranding lay length, lay ratio, stranding factor, and lay angle were integrated to construct a coupled parametric kinematic model; electromagnetic simulations of the star quad were performed with simulation software over a lay-ratio range of 15~25, and the influence of the detwisting transmission ratio on the wrinkling of the shielding layer was analyzed. The simulation results indicated that, when the lay ratio was reduced from 22 to 18, the capacitance coupling coefficient of the unshielded star quad decreased from 93 pF·km−1 to 78 pF·km−1; when the detwisting transmission ratio was controlled within 0.95~1.05, the near-end crosstalk (NEXT) attenuation at 1000 kHz was increased from 52 dB to above 56 dB. It was concluded that simulation-driven process optimization based on the coupled parametric model could serve as a feasible approach to shortening the process commissioning time and improving the yield, while also providing quantifiable theoretical support for the manufacturing of high-speed railway digital signal cables.

       

    • ©上海电缆研究所有限公司《电线电缆》编辑部版权所有,未经授权不得转载、改编。

    /

    返回文章
    返回